Sale!

Yokogawa 240634

Original price was: $396.26.Current price is: $288.91.

99 in stock

SKU: 240634 Category:

Description

  • Analog models with two and three rating
  • AC voltage measurement
  • Automatic discharge
  • Sky blue EL backlight
  • Increased safety (covered battery charger)
  • Rating: 250V/50M~
  • Effective Measuring Range: 0.01-50M~
  • Central Scale Value: 1M~
  • AC Voltage Measurement: 0 to 300 V
  • Lower Limit: 0.25~
  • Rated Current: 1 mA
  • Approx. Outer Scale Length: 88 mm
  • Discharge Function: Tester automatically begins discharge when you turn off MEAS switch; pointer swings if there is any residual voltage in circuit under test; you can make sure discharge is complete by checking that pointer swings back to infinite
  • Batteries: Six AA (R6P) batteries
  • Standard Test Conditions
  • Ambient Temperature/Humidity Ranges: 23 ±5 /45-75% RH
  • Position of Use: Horizontal (5º max. of angle of inclination)
  • External Magnetic Fields: None Battery voltage: Within effective voltage range (The pointer must stay within the range indicated by the BAT symbol when the battery check is performed.)
  • Tolerance Mentioned Conditions:
  • Resistance measurement: First effective measuring range = ±5% of reading
  • Second effective measuring range = ±10% of reading
  • Infinite and zero scale values: 0.7% max. of scale length
  • AC voltage: ±10% of maximum scale value
  • No-load voltage: 130% max. of rated voltage
  • Rated measuring current: 1 mA (0 to 20%) when in first effective measuring range
  • Short-circuit current: 12 mA max.