Description

  • Test adapter for electric vehicle charging stations
  • Test functionality and safety of electrical vehicle charging stations, easily and reliably with FEV100 Adapter Kit
  • Vehicle simulation: CP Control Pilot state simulation tests different charging states
  • Grounding protection: PE Pre-Test for dangerous voltage
  • GFCI testing: Stay protected from and check risk of electric shock
  • Compatibility: Integrates into Fluke portfolio of test and measurement tools
  • SAE J1772: Complies with North American standards

General specifications

  • Input voltage: UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10 % voltage fluctuations from nominal 2
  • EV connector (EVC-13): SAE J1772 socket, 16 A (type 1, 5P single-phase)
  • Internal power consumption: 2 W max
  • Operating temperature: -4 °F to 104 °F (-20 °C to 40 °C)
  • Storage temperature: -4 °F to 122 °F (-20 °C to 50 °C)
  • Operating humidity range: 10% to 85% relative humidity non-condensing
  • Storage relative humidity: 0% to 85% non-condensing
  • Operating altitude: 6561 ft (2000 m) max
  • Safety standards: IEC 61010-1, Pollution Degree 2; IEC 61010-2-030
  • Measurement category: CAT II 250 V
  • IP protection class: IP54

Electromagnetic Compatibility (EMC)

  • International:
    • IEC 61326-1: Basic Electromagnetic Environment
    • CISPR 11: Group 1, Class A
    • Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for internal function of equipment itself
    • Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes; there may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances
    • Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments
  • USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103

Functions

  • CP states: A, B, C, D
  • CP error: “E” On/off
  • PE error: On/off
  • GFCI test: Yes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms
  • PE pre-test (typical): Visible indication>30 V on PE conductor

Outputs (for test purpose only)

  • Measuring terminals L1, L2/N, PE: Max 250 V 50/60 Hz, CAT II 250 V
  • CP signal output terminals: Approximately ±12 V (under normal conditions), in case of wrong wiring or error of charging station these terminals can be hazardous ≥ max 250 V against PE